pimd,pim6d: Resolving the YANG datatype Inconsistency for PIM Hello Interval

The YANG specification currently designates a uint8 data type for the hello interval,
despite the CLI documentation (ip pim hello (1-65535) [(1-65535)]) indicating a maximum value of 65535.
To address this inconsistency, updating the data type to uint16 allowing for a maximum value for hello intervals.

Signed-off-by: Sai Gomathi N <nsaigomathi@vmware.com>
This commit is contained in:
Sai Gomathi N 2023-08-30 05:45:18 -07:00
parent 497584ac48
commit dd1e34eff4
2 changed files with 2 additions and 2 deletions

View File

@ -1633,7 +1633,7 @@ int lib_interface_pim_address_family_hello_interval_modify(
ifp = nb_running_get_entry(args->dnode, NULL, true);
pim_ifp = ifp->info;
pim_ifp->pim_hello_period =
yang_dnode_get_uint8(args->dnode, NULL);
yang_dnode_get_uint16(args->dnode, NULL);
pim_ifp->pim_default_holdtime = -1;
break;
}

View File

@ -343,7 +343,7 @@ module frr-pim {
}
leaf hello-interval {
type uint8 {
type uint16 {
range "1..max";
}
default "30";